IEEE C37 013 PDF

Tested to IEEE C and Ca standard for generator circuit breakers. Meets or exceeds the latest ANSI, IEEE and NEMA standards. Up to 50 full-fault. latest standards, the previous IEEE C (now superseded) and the IEC for distribution circuit-breakers, in terms of requirements including short. The specific IEEE Standard is C, entitled “IEEE Standard for AC. High-Voltage Generator Circuit Breakers Rated on a. Symmetrical Current Basis” .

Author: Kigakinos Samuzil
Country: Kazakhstan
Language: English (Spanish)
Genre: Love
Published (Last): 7 July 2009
Pages: 56
PDF File Size: 9.47 Mb
ePub File Size: 8.54 Mb
ISBN: 559-6-32483-815-8
Downloads: 72675
Price: Free* [*Free Regsitration Required]
Uploader: Bam

Showing of 3 extracted citations. Faculty Electrical Engineering, Mathematics and Computer Science Department Electrical Sustainable Energy Date Abstract The requirements imposed on generator circuitbreakers greatly differ from the requirements imposed on other transmission and distribution circuit-breakers.

Showing of 13 references. However, further calculations are needed to determine the duty for a special-purpose generator circuit breaker. From This Paper Figures, tables, and topics from this paper.

In order to quantify the transient recovery voltage requirements for the application of generator circuit-breakers a comprehensive survey of 0113 fault conditions occurring in several power stations has been performed.

References Publications referenced ieeee this paper. Due to the location of installation between the generator and the associated step-up transformer, a generator circuit-breaker must meet high technical requirements with respect to rated normal currents, short-circuit currents, fault currents due to out-of-phase conditions and transient recovery voltages.

Electrical Engineering, Mathematics and Computer Science. Subject fault current generator circuit-breaker transient recovery voltage To reference this document use: North American and IEC standards for circuit breakers. Estimation of short circuit capability of Generator Circuit Breaker for a generator fed fault K.

  THAI FOR BEGINNERS BENJAWAN POOMSAN BECKER EPUB DOWNLOAD

IEEE C37.013

The testing of SF6 generator circuit-breakers. Citations Publications citing this paper. Currently, commercially available software products help in determining the duty for a general-purpose circuit breaker. Delayed current zero due to out-of-phase synchronizing.

Skip to main content.

Evaluating Generator Circuit Breakers Short-Circuit Duty Using IEEE C37.010 and C37.013

Circuit Breaker Device Component. Elements of Power System Analysis, 3rd ed. The requirements imposed on generator circuitbreakers greatly differ from the requirements imposed on other transmission and distribution circuit-breakers. Application Of vacuum circuit-breaker to clear faults with delayed current zeros.

Short Circuit Calculation | Short Circuit Software | Fault Analysis

Skip to search form Skip to main content. Assessment of the delayed current zeros occurrence using the evaluation of the Z-bus matrix in Matpower toolkit Vladimir VajnarZdenek VostrackyBarry Rawn 18th International Scientific Conference on….

Circuit Breaker Device Component Search for additional papers on this topic.

Topics Discussed in This Paper.